VanTsteri introduces a gaseous hydrogen peroxide concentration probe with a measurement range of 0–2000 ppm. The probe also detects and displays temperature and relative humidity. Configurable addresses support data collection from probes installed at different locations.

Local readings at each monitoring point

The probe’s small display shows the hydrogen peroxide concentration, temperature and relative humidity at its own monitoring point. This provides a local view of concentration and environmental conditions.

Design illustration of a VanTsteri gaseous hydrogen peroxide probe with a local temperature and humidity display
Design illustration; displayed values are illustrative. Final enclosure and interfaces subject to engineering confirmation.

Centralized display for multiple points

The accompanying independent display terminal is designed to show readings and connection status from multiple monitoring points in one place.

For applications requiring several points, probe placement can reflect the space layout and monitoring needs. A compatible data-acquisition or monitoring system can be used to view changes at different locations. The supported number of probes, display functions and recording arrangements must be confirmed for the accompanying system.

Design illustration of a VanTsteri independent multi-point display showing illustrative hydrogen peroxide, temperature, humidity and connection data
Design illustration; displayed values are illustrative. Final enclosure and interfaces subject to engineering confirmation.

Digital and analog outputs for system integration

The probe provides RS485 / Modbus RTU digital communication and a 4–20 mA analog output. It uses a 12–24 VDC power supply and supports zero and span calibration. Customers can discuss probe integration and display configuration in relation to the interfaces on their existing equipment and monitoring systems.

Key product specifications

Hydrogen peroxide measurement range 0–2000 ppm
Resolution 1 ppm
Accuracy ±10 ppm or ±5% of reading, whichever is greater
Response time T90 ≤60 s
Humidity condition 10–95% RH, non-condensing
Temperature and humidity functions Temperature and humidity compensation; temperature and relative humidity detection and display
Ingress protection IP65

Specifications are provided by VanTsteri. The accompanying images illustrate a design direction; final enclosure and interface details require engineering confirmation.

Configure around the monitoring requirement

Customers can provide the application, number of monitoring points, installation environment and interface requirements to discuss a suitable configuration.

Concentration, temperature and humidity data should be used alongside process records, effectiveness evaluation and site safety requirements. These readings alone do not establish sterilization effectiveness or permission for personnel entry.

Explore H2O2 probe

Discuss concentration monitoring and multi-probe configuration