KINO PRO
Autonomous movement for suitable cleanrooms and controlled spaces.
Concentration and environmental monitoring
US9 / unit · 1–4 units · View volume pricing
Local concentration, temperature and relative humidity readings.
The probe measures gaseous hydrogen peroxide over 0–2000 ppm, with a local display for concentration, temperature and relative humidity. Configurable probe addresses support monitoring at different locations.
RS485 / Modbus RTU digital communication and a 4–20 mA analog output support system integration. The probe uses 12–24 VDC power and supports zero and span calibration.

The independent display terminal is designed to show readings and connection status from multiple monitoring points.
Probe placement can reflect the space layout and monitoring needs. A compatible data-acquisition or monitoring system can show changes at different locations. Supported probe count, display functions and recording arrangements require confirmation for the accompanying system.
Discuss installation conditions and interface requirements for existing equipment and monitoring systems.

Concentration, temperature and humidity readings should be used alongside process records, effectiveness evaluation and site safety requirements. These readings alone do not establish sterilization effectiveness or permission for personnel entry.
VanTsteri · VHP monitoring
US$649 / unit
Standard price for orders of 1–4 units.
Designed for VHP bio-decontamination process monitoring and OEM integration.
Made to order. Production lead time: 15 days after order confirmation. Shipping transit time is additional and will be confirmed in your quotation.
| Order quantity | Price per unit |
|---|---|
| 1–4 units | US$649 |
| 5–9 units | US$599 |
| 10–19 units | US$549 |
| 20+ units | Request a quotation |
Prices in USD. Shipping, import duties and applicable taxes are excluded. Final pricing is subject to order confirmation.
Volume discounts are available for bulk orders and OEM projects. Contact VanTsteri for quotations, sample orders and distributor pricing.
Specifications are supplied by VanTsteri. Confirm the final configuration, enclosure, interfaces and included accessories in your quotation. Monitoring readings alone do not establish decontamination efficacy or permission for personnel entry.
PRODUCT DATA
Complete specification table supplied by VanTsteri, including communication, power, calibration and networking.
| Measurement | Vaporized hydrogen peroxide (H2O2) |
|---|---|
| Measurement range | 0–2000 ppm |
| Resolution | 1 ppm |
| Accuracy | ±10 ppm or ±5% of reading, whichever is greater |
| Response time | T90 ≤60 s |
| Operating temperature | 0–50 °C |
| Humidity condition | 10–95% RH, non-condensing |
| Temperature & humidity compensation | Supported |
| Temperature & relative humidity display | Detection and display on the probe’s local screen; centralized display design for multiple monitoring points |
| Digital output | RS485 / Modbus RTU |
| Analog output | 4–20 mA |
| Power supply | 12–24 VDC |
| Ingress protection | IP65 |
| Calibration | Zero + span |
| Networking | Multiple probe addresses |
Specifications provided by VanTsteri. The images illustrate a design direction; final enclosure and interface details require engineering confirmation.
The probe measures gaseous hydrogen peroxide over 0–2000 ppm with 1 ppm resolution. Its local screen also displays temperature and relative humidity.
The probe provides RS485 / Modbus RTU digital communication and a 4–20 mA analog output. It requires a 12–24 VDC power supply.
Configurable probe addresses support multi-point monitoring with a compatible system. Supported probe count, display functions and recording arrangements require confirmation for the accompanying system.
The operating temperature is 0–50 °C, with 10–95% RH in non-condensing conditions. Zero and span calibration are supported.
No. These readings alone do not establish sterilization effectiveness or permission for personnel entry. Use them alongside process records, effectiveness evaluation and site safety requirements.
Selection & configuration
For a probe enquiry, state the expected concentration range, installation environment, number of monitoring points and the receiving control system. Confirm the required digital or analog output, addressing, calibration documentation and final enclosure and interfaces. The probe monitors conditions; it is separate from the equipment used to carry out decontamination.
Compare deployment and test conditions →
Autonomous movement for suitable cleanrooms and controlled spaces.
Portable equipment positioned by your team in suitable enclosed spaces.
Equipment-specific applications in pipelines, tanks and chambers; HVAC configuration by project.
Provide the application, number of monitoring points, installation environment and interface requirements.
Discuss concentration monitoring and multi-probe configurationOptional analytics helps us understand page visits and saved enquiries. Google Analytics loads only if you accept. Rejecting does not affect your enquiry.
Privacy Notice